Digital Outputs
Each sensor has two optically isolated outputs. Both outputs are open collector and open emitter, which allows a variety of power sources to be connected and a variety of signal configurations.
Digital outputs cannot be used when taking scans using the Snapshot button, which takes a single scan and is typically used to test measurement tool settings. Digital outputs can only be used when a sensor is running, taking a continuous series of scans. |
Out_1 (Collector – Pin
Function |
Pins |
Max Collector Current |
Max Collector–Emitter Voltage |
Min Pulse Width |
---|---|---|---|---|
Out_1 |
N, O |
40 mA |
70 V |
20 µs |
Out_2 |
S, T |
40 mA |
70 V |
20 µs |
The resistors shown above are calculated by R = (V+) / 2.5 mA.
The size of the resistors is determined by power = (V+)^2 / R.
Inverting Outputs
To invert an output, connect a resistor between ground and Out_1- or Out_2- and connect Out_1+ or Out_2+ to the supply voltage. Take the output at Out_1- or Out_2-. For resistor selection, see above.