Start

The Start command starts the sensor system (system enters the Running state). For more information on states, see States.

Command

Field

Type

Offset

Description

length

32u

0

Command size including this field, in bytes.

id

16u

4

Command identifier (0x100D).

Reply

Field

Type

Offset

Description

length

32u

0

Reply size including this field, in bytes.

id

16u

4

Reply identifier (0x100D).

status

32s

6

Reply status. For a list of status codes, see Status Codes.